Assessment
Why it matters
CISA lists this vulnerability as known to be exploited; exploitation is confirmed; EPSS is 89.6%; technical severity is CVSS 7.2.
A command injection vulnerability in D-Link DIR-823X 240126 and 240802 allows an authorized attacker to execute arbitrary commands on remote devices by sending a POST request to /goform/set_prohibiting via the corresponding function, triggering remote command execution.
Who should care
- Teams operating DIR-823X, Dir-823x Firmware
- Vulnerability and exposure management teams
- Security operations teams monitoring exploitation activity
Response plan
What I would do
- Confirm whether DIR-823X, Dir-823x Firmware is present in the environment.
- Identify affected versions and establish whether vulnerable services are exposed or reachable.
- Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable.
- Review relevant security telemetry for evidence of attempted or successful exploitation.
- Document the remediation decision and track it to verified completion.
Treatment intelligence
Remediation intelligence
Vendor sources are listed before government and third-party guidance. Confirm product applicability and change prerequisites before deployment.
Technical details
- CVSS vector
- CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
- CWE
- CWE-77
- Affected versions
- D-Link DIR-823X; Dlink Dir-823x Firmware (Version 240126 | Version 240802)
- Fixed versions
- No explicit fixed version is currently recorded.
- Published
- 25 March 2025
- Attack vector
- Network
- Privileges required
- High
- User interaction
- None
Signal timeline
- CVE published
- Added to CISA KEV
- Latest EPSS score: 89.6%