Skip to content
Weekly Signal
Live intelligence Updated 19 Aug 2026 · 13:41 UTC

SonicWall · SMA1000 Appliances, Sma6210 Firmware, Sma7210 Firmware +1 more

CVE-2026-15410

SonicWall SMA1000 Appliances Code Injection Vulnerability

Recommended action

Validate affected assets and exposure now, then remediate on an accelerated schedule. Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.

View response plan
CVSS7.2
EPSS76.3%
KEVYes
ExploitationConfirmed exploitation
PatchPatch or guidance available ↓

Assessment

Why it matters

CISA lists this vulnerability as known to be exploited; exploitation is confirmed; EPSS is 76.3%; technical severity is CVSS 7.2.

Post-authentication improper control of generation of code ('Code Injection') vulnerability has been identified in the SMA1000 Appliance Management Console (AMC) which in specific conditions could potentially enable a remote authenticated attacker as administrator to execute arbitrary OS commands.

Who should care

  • Teams operating SMA1000 Appliances, Sma6210 Firmware, Sma7210 Firmware +1 more
  • Vulnerability and exposure management teams
  • Security operations teams monitoring exploitation activity

Response plan

What I would do

  1. Confirm whether SMA1000 Appliances, Sma6210 Firmware, Sma7210 Firmware +1 more is present in the environment.
  2. Identify affected versions and establish whether vulnerable services are exposed or reachable.
  3. Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.
  4. Review relevant security telemetry for evidence of attempted or successful exploitation.
  5. Document the remediation decision and track it to verified completion.

Vendor remediation

Patch and remediation links

Use the vendor source below to confirm the correct fixed version, package or mitigation for your affected product.

Technical details

CVSS vector
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
CWE
CWE-94
Affected versions
SonicWall SMA1000 Appliances; SonicWall Sma6210 Firmware (Version: 12.5.0-02800); SonicWall Sma7210 Firmware (Version: 12.5.0-02800); SonicWall Sma8200v (Version: 12.5.0-02800)
Published
14 July 2026
Attack vector
Network
Privileges required
High
User interaction
None

Signal timeline

  1. CVE published
  2. Added to CISA KEV
  3. Latest EPSS score: 76.3%
  4. Signal calculated at 83

External references